Brand Name: | GENY |
Model Number: | YCS-103 |
MOQ: | 1 pcs |
Price: | negotiation |
Payment Terms: | L/C,T/T,D/P |
Supply Ability: | 30 PCS per month |
• Ultra-high accuracy and long-term stability for demanding calibration tasks
• RS232 interface for seamless integration into automated production lines
• Optional keypad for quick on-site manual control
• 2nd–21st harmonic: amplitude and phase fully programmable to replicate real-world grid conditions
• Lightweight, rugged aerospace-grade aluminum alloy housing—corrosion-resistant for tropical humidity
• Built-in protection against overload, short-circuit (voltage) and open-circuit (current) for 24/7 safe operation
• Intuitive bilingual control software (English/Chinese interface) – zero learning curve, ready in minutes
• National power utilities
• Government metrology & certification bureaus
• Leading energy-meter manufacturers (OEM/ODM support)
• International-grade quality, compliant with IEC 61000 & ANSI C12.20
• High power output: up to 1000 VA (voltage) / 1500 VA (current) – one unit replaces multiple sources
• Industry-leading power stability: temp drift <50 ppm/°C, annual drift <0.01 %
• Total harmonic distortion <0.3 % on linear resistive load for trustworthy calibration results
|
YCS-103-250 |
YCS-103-600 |
YCS-103-1200 |
YCS-103-2500 |
Voltage |
||||
Test voltage output (Phase-Neutral) |
3×(24V – 288V) or customized |
|||
Power of the voltage output |
3×100VA |
3×250VA |
3×500VA |
3×1000VA |
Resolution |
Better than 0.01% of full scale value of range |
|||
Setting accuracy |
Better than 0.05% at the final range value |
|||
Stability |
Better than 0.005%/h (integration time 150 s) |
|||
Load regulation from 0-max. load |
< 0.01% |
|||
Distortion factor |
< 0.3% for linear resistance load |
|||
Harmonics |
2nd – 21st free programmable |
|||
Current |
||||
Test current output |
3×(1mA – 100A) |
|||
Power of the current output |
3×150VA |
3×350VA |
3×750VA |
3×1500VA |
Resolution |
Better than 0.01% of full scale value of range |
|||
Setting accuracy |
Better than 0.05% at the final range value |
|||
Stability |
Better than 0.005%/h (integration time 150 s) |
|||
Load regulation from 0-max. load |
< 0.01% |
|||
Distortion factor |
< 0.3% for linear resistance load |
|||
Harmonics |
2nd – 21st free programmable |
|||
Phase angle |
||||
Range |
0 -- 360° |
|||
Resolution |
0.01° |
|||
Setting accuracy |
0.1° |
|||
Frequency |
||||
Range |
45Hz – 65Hz |
|||
Resolution |
0.01Hz |
|||
|
||||
Voltage Supply |
3×220/380V±10% or customized 50/60Hz±2Hz |
|||
Ambient temperature |
-10°C -- +40°C |
|||
Relative humidity |
35% -- 85% |