Brand Name: | GENY |
Model Number: | YC1893/1D |
MOQ: | 1 pcs |
Price: | negotiation |
Payment Terms: | L/C,T/T,D/P |
Supply Ability: | 30 PCS per month |
1. Nation-level utility companies
2. Governmental bureaus of metrology
3. Big energy meter manufacturers
|
YC1891D-6 |
YC1891D-12 |
YC1891D-24 |
YC1891D-48 |
Number of meter positions |
6 |
12 |
24 |
48 |
Accuracy |
0.05 |
|||
Power Source |
YCS-101-250 |
YCS-101-600 |
YCS-101-1200 |
YCS-101-2500 |
Standard Meter |
SZ01A-K3 |
|||
MSVT |
HJ200GL-6 |
HJ200GL-12 |
HJ200GL-24 |
HJ200GL-48 |
QCD |
D5 series |
|||
Scanning Head |
YCG-2 series |
|||
Voltage |
||||
Test voltage output |
24V – 288V or customized |
|||
Power of the voltage output |
100VA |
250VA |
500VA |
1000VA |
Resolution |
Better than 0.01% of full scale value of range |
|||
Setting accuracy |
Better than 0.05% at the final range value |
|||
Stability |
Better than 0.005%/h (integration time 150 s) |
|||
Load regulation from 0-max. load |
Better than 0.01% |
|||
Distortion factor |
Better than 0.3% for linear resistance load |
|||
Harmonics |
2nd – 21st free programmable |
|||
Current |
||||
Test current output |
1mA – 100A or customized,Max.200A |
1mA – 100A |
||
Power of the current output |
150VA |
350VA |
750VA |
1500VA |
Resolution |
Better than 0.01% of full scale value of range |
|||
Setting accuracy |
Better than 0.05% at the final range value |
|||
Stability |
Better than 0.005%/h (integration time 150 s) |
|||
Load regulation from 0-max. load |
Better than 0.01% |
|||
Distortion factor |
Better than 0.3% for linear resistance load |
|||
Harmonics |
2nd – 21st free programmable |
|||
Phase angle |
||||
Range |
0 -- 360° |
|||
Resolution |
0.01° |
|||
Setting accuracy |
0.1° |
|||
Frequency |
||||
Range |
45Hz – 65Hz |
|||
Resolution |
0.01Hz |
|||
Error display |
||||
Type of error display |
Red LED |
|||
Resolution of the error displays |
8 digits |
|||
|
||||
Voltage Supply |
220V±10% or customized 50/60Hz±2Hz |
3x220/380V±10% or customized 50/60Hz±2Hz |
||
Ambient temperature |
-10°C -- +40°C |
|||
Relative humidity |
35% -- 85% |
Technical spec. |
YC1893D-6 |
YC1893D-12 |
YC1893D-24 |
YC1893D-48 |
Number of meter positions |
6 |
12 |
24 |
48 |
Accuracy |
0.05 / 0.02 |
|||
Power Source |
YCS-103-250 |
YCS-103-600 |
YCS-103-1200 |
YCS-103-2500 |
Standard Meter |
SZ03A-K6 / SZ03A-K8 |
|||
Scanning Head |
YCG-S Series |
|||
Voltage |
|
|||
Test voltage output(Phase-Neutral) |
3x(24V~288V)(or customized) |
|||
Power of the voltage output |
Max. 3x100VA |
Max. 3x250VA |
Max. 3x500VA |
Max. 3x1000VA |
Resolution |
Better than 0.01% of full scale value of range |
|||
Setting accuracy |
Better than 0.05% at the final range value |
|||
Stability |
Better than 0.005% /h (integration time 150s) |
|||
Load regulation from 0~max. load |
Better than 0.01% |
|||
Distortion factor |
Better than 0.3% for linear resistance load |
|||
Harmonic |
2nd~21st free programmable |
|||
Current |
|
|||
Test current output |
3x(1mA~100A) |
|||
Power of the current output |
Max. 3x150VA |
Max. 3x350VA |
Max. 3x750VA |
Max. 3x1500VA |
Resolution |
Better than 0.01% of full scale value of range |
|||
Setting accuracy |
Better than 0.05% at the final range value |
|||
Stability |
Better than 0.005% /h (integration time 150s) |
|||
Load regulation from 0~max. load |
Better than 0.01% |
|||
Distortion factor |
Better than 0.3% for linear resistance load |
|||
Harmonic |
2nd~21st free programmable |
|||
Phase angle |
|
|||
Range |
0~360⁰ |
|||
Resolution |
0.01⁰ |
|||
Setting accuracy |
0.1⁰ |
|||
Frequency |
|
|||
Range |
45Hz~65Hz |
|||
Resolution |
0.01Hz |
|||
Error display |
|
|||
Type of error display |
Red LED |
|||
Resolution of error displays |
8 digitals |
|||
Other |
|
|||
Voltage supply |
3x220/380V±10%(or customized) 50/60Hz ±2Hz |
|||
Ambient temperature |
-10°C~+40°C |
|||
Relative humidity |
35%~85% |