Brand Name: | GENY |
Model Number: | YC1893D-12 |
MOQ: | 1 Set |
Payment Terms: | L/C,T/T,D/P |
The meter test system supports the testing of mechanical meters, electromechanical meters, and electronic meters, offering automatic, semi-automatic, or manual operation to meet various testing needs.
Compatible with multiple wiring configurations including 3P4W, 3P3W, and 1P2W, suitable for wide utility applications.
Supports comprehensive testing modes: active power, reactive power, and cross-connected reactive power.
Capable of simultaneously testing meters with the same specifications but different meter constants, improving productivity.
Features automatic positioning of the rotor mark on mechanical meters, increasing efficiency and reducing manual intervention.
Includes starting and creeping tests as part of standard verification routines.
Optional neutral current test is available to meet extended testing requirements.
Supports optional ICT installation at each meter position, enabling precise testing of three-phase meters with closed current-voltage (I-P) links.
Equipped with protection functions against overload, voltage short circuit, and current open circuit, ensuring safety during operation.
The swinging scanning head design simplifies control and enhances ease of operation.
Constructed with lightweight aluminum alloy, offering high strength, corrosion resistance, and easy mobility—ideal for a wide range of working environments.
The testing software features a user-friendly interface, compatible with Windows 2000 / XP / 7 / 8 / 10, and supports multilingual customization for easy use and training.
Software includes all essential testing modules for modern energy meters: error test, harmonic test, demand test, and influence quantity test, ensuring complete and reliable performance.
Voltage |
|
Test voltage output (Phase-Neutral) |
3x(24 – 300 V) |
Power of the voltage output |
3×1000VA |
Resolution |
Better than 0.01% of full scale value of range |
Setting accuracy |
Better than 0.05% at the final range value |
Stability |
Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load |
< 0.01% |
Distortion factor |
< 0.3% for linear resistance load |
Harmonics |
2nd – 21st free programmable |
Current |
|
Test current output |
1 mA – 120 A |
Power of the current output |
3×2000VA |
Resolution |
Better than 0.01% of full scale value of range |
Setting accuracy |
Better than 0.05% at the final range value |
Stability |
Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load |
< 0.01% |
Distortion factor |
< 0.3% for linear resistance load |
Harmonics |
2nd – 21st free programmable |
Phase angle |
|
Range |
0 -- 360° |
Resolution |
0.01° |
Setting accuracy |
0.1° |
Frequency |
|
Range |
45 Hz – 65 Hz |
Resolution |
0.01 Hz |