Brand Name: | GENY |
Model Number: | YC1893D |
MOQ: | 1 |
Price: | negotiate rates |
Payment Terms: | T/T, L/C, D/P, T/T |
Supply Ability: | 5 sets / 1 months |
Voltage |
3 × 220V±10% |
Frequency |
50 / 60Hz ± 2Hz |
Power capacity |
>6k VA |
Ambient temperature |
-10°C -- +40°C |
Relative humidity |
35% -- 85% |
Voltage output |
|
Test voltage output (Phase-Neutral) |
3 × (24V – 300V) |
Power of the voltage output |
3 × 1000VA |
Resolution |
Better than 0.01% of full scale value of range |
Setting accuracy |
Better than 0.05% at the final range value |
Stability |
Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load |
Better than 0.01% |
Distortion factor |
Better than 0.3% for linear resistance load |
Harmonics |
2nd – 21st free programmable |
Current output |
|
Test current output |
3 × (0.3mA – 20A) |
Power of the current output |
3 × 1500VA |
Resolution |
Better than 0.01% of full scale value of range |
Setting accuracy |
Better than 0.05% at the final range value |
Stability |
Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load |
Better than 0.01% |
Distortion factor |
Better than 0.3% for linear resistance load |
Harmonics |
2nd – 21st free programmable |
Phase angle |
|
Range |
0 -- 360° |
Resolution |
0.01° |
Setting accuracy |
0.1° |
Frequency |
|
Range |
45Hz – 65Hz |
Resolution |
0.01Hz |
If you would like to explore further details, please navigate to the following URL:http://www.genymetertestequipment.com/