Brand Name: | GENY |
Model Number: | YC1893R |
MOQ: | 1 Piece |
Price: | negotiation |
Payment Terms: | L/C,T/T,D/P |
Supply Ability: | 10 PCS per month |
The YC-1893R series three-phase electrical energy standard verification equipment is a high-grade three-phase standard system developed by our company, featuring world-class performance comparable to similar international systems. With an overall accuracy class of 0.01, this premium standard electrical energy testing equipment is tailor-made for institutions such as national and provincial/municipal metrology institutes, electrical power research institutes, and manufacturers of electrical energy metering products. It is primarily used to establish primary standards or serve as a working standard for verifying reference meters.
Measurement of active power, reactive power, active energy, and reactive energy
Start-up and creep testing
Automatic index mark detection for accelerated creep/start-up testing
Measurement of fundamental error, mean error, standard deviation, and 24-hour variation
Voltage influence, frequency influence, harmonic influence (2nd-21st order), and phase sequence influence testing
Simultaneous verification of standard energy meters with identical voltage/current parameters but different meter constants
Integrated current open-circuit protection and voltage short-circuit protection
Dual operation modes: automatic and manual
Automated error data processing, storage, and real-time output via software
Advanced data management and statistical analysis with configurable reporting formats
Barcode scanner compatibility
Precision power supply design eliminating beat frequency interference
Site-specific structural configuration
Device Accuracy Class |
0.01% or 0.02% |
Power Supply |
3P4W 3×380V±10%, 50Hz±2Hz |
Ambient Temperature |
-10℃ ... +40℃ (Standard Operating Temperature: 20℃±1℃) |
Ambient Humidity |
35% ... 95% (Standard Operating Humidity: 50%R.H±15%R.H) |
Output Voltage Range (L-N) |
3×40V ... 450V |
Output Voltage Power |
3×200VA |
Voltage Resolution |
0.001% |
Voltage Stability |
0.002%/120s |
Load Change Rate |
0.01% |
Voltage Distortion |
0.05% (Across the Entire Linear Load Range) |
Output Current Range |
3×1mA ... 120A (Up to 230A Current as Per Customer Request) |
Output Current Power |
3×300VA |
Current Resolution |
0.001% |
Current Stability |
0.002%/120s |
Current Distortion |
0.05% (Across the Entire Linear Load Range) |
Phase Adjustment Range |
0° ... 360° |
Phase Resolution |
0.01° |
Frequency Adjustment Range |
45Hz ... 65Hz |
Frequency Resolution |
0.001Hz |
Power Output Stability |
0.002%/120s |
Continuous Current |
100A |
Maximum Continuous Current for 20 Minutes |
120A |
Frequency Response |
2MHz |
Error Display Method |
LED Display (One Display Window per Meter Position) |