![]() |
Brand Name: | GENY |
Model Number: | YC1893D |
MOQ: | 1 Piece |
Price: | negotiation |
Payment Terms: | L/C,T/T |
Supply Ability: | 30 PCS per month |
1. The installation of ICT in each meter position is required to test three-phase meters with closed links between the current and voltage measuring circuits (I-P links).
2. The meter test system is capable of measuring mechanical and electronic meters, as well as electronic meters, through automatic, semi-automatic or manual operation.
3.Meters under testing: The following configurations are available: 3P4W, 3P3W and 1P2W.
Fourthly, the testing mode encompasses the following: active power, reactive power and cross-connected reactive power.
In order to ensure the accuracy of the measurements, it is essential to simultaneously measure meters that have the same specifications but different meter constants.
6. The automatic positioning rotor mark of the disc of the mechanical meter is more efficient.
7. Initiating the test and the creep test.
8. The product incorporates a range of safety features, including overload, short-voltage and open-current circuit protection.
9. The synchronised movement of the scanning heads streamlines the control process.
10. This aluminium alloy is both lightweight and durable, while also being resistant to corrosion.
11. The testing software, compatible with Windows 2000, XP, 7, 8 and 10, includes a range of functional modules for various modern energy meters. These modules facilitate testing for real-time error, harmonic, demand and influence, among others.
Technical spec. | YC1893D-ICT-6 | YC1893D-ICT-12 | YC1893D-ICT-24 | YC1893D-ICT-48 |
Number of meter positions equipped ICT | 6 | 12 | 24 | 48 |
Accuracy class of ICT | 0.05 / 0.01 | |||
Accuracy | 0.05 | |||
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Standard Meter | SZ03A-K6 / SZ03A-K8 (customized) | |||
Scanning Head | YCG-S Series | |||
Voltage | ||||
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Current | ||||
Test current output | 3x(1mA~100A) | |||
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Phase angle | ||||
Range | 0~360⁰ | |||
Resolution | 0.01⁰ | |||
Setting accuracy | 0.1⁰ | |||
Frequency | ||||
Range | 45Hz~65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of error displays | 8 digitals | |||
Other | ||||
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
Ambient temperature | -10°C~+40°C | |||
Relative humidity | 35%~85% |
If you would like to learn more, please visit our official website:http://www.genymetertestequipment.com/
Youtube Subscription: Product Video and Operating Instructions Overview :https://www.youtube.com/@genyguangzhouchina7498